<tfoot id="qx2gz"></tfoot><pre id="qx2gz"></pre>

      
      
    1.   Location: Home > Products >  Automatic Fire Alarm and Linkage Control System >  Controller
      Products
      Broadcast System Repeater Controller Modules Sound and Light Alarm Detector The Internet Manual Call Point Telephone System Power Supply Explosion-Proof Series
      Fire Alarm Control Unit(JB-TGL-EI8000G/JB-TTL- EI6000T)
      Product Overview:



      Overview:

       EI8000G/ EI8000T fire alarm controller (linkage type) integrates various functions such as fire alarm, linkage control, supervision alarm, anti-theft alarm, flammable gas alarm, intercom telephone,network communication, etc. It is suitable for all kinds of hotels, office buildings .Large and medium-sized fire alarm projects such as buildings, residential buildings, gymnasiums, libraries, and various warehouses.

       


      Basic Functions:

      Fire alarm functioncan receive fire alarm signals through fire detectors such as smoke detectors, heat detectors, relay modules, manual call point, etc., and display fire alarm information. Composite        judgment can be made based on adjacent detectors.

      Supervision alarm function: can receive the supervision alarm signals such as burglary alarm and gas alarm through the input module, and can realize linkage.

      Shielding function: can shield various bus components and the fire sound strobe alarm output.

      Fault detection function: can automatically detect line faults, component faults, power faults, etc., and issue fault alarms with sound and light signals to display fault information.

      System test function: can log in part number and current address, can directly set and program address; can check detector detection value; Ability to self-test any part of the loop.


      Special Functions:

      Linkage control function: The EI series input/output modules can be connected via four buses (including 24V power lines), and various types of fire-fighting equipment can be controlled in a flexible and diverse manner according to the alarm information, and the linkage points are not limited, and the user's needs can be met to the maximum extent. Displays feedback information about device actions, including device type, module type, module address, installation location, and action time.

      Optional bus linkage control panel, through programming can realize control of various types, zones, and specific components.

      Optional multi-line linkage control panel, direct output linkage control, 12 sets of multi-line linkage buttons for each control panel, used to control important equipment such as fire pump, spray pump and exhaust fan. When the multi-line linkage panel exceeds 2 blocks, the external control power supply needs to be configured for the power supply of the multi-line linkage panel.

      Be provided with gas fire extinguishing function, gas fire extinguishing equipment can be connected by bus to realize manual/automatic

      Manual/automatic switching is possible. in the manual state, any device can be started or stopped by type, partition or address through menu selection.

      System compatible function: It can be set as a centralized controller, zone controller or independent fire alarm controller on site, and can form a network communication system through EICAN/EINet?.

      The zones controller can automatically upload fire alarm, linkage control, fault alarm, supervision alarm, shielding, delay, self-test and other information to the centralized controller, and should be able to receive and process the relevant instructions of the centralized controller.

      The centralized controller can receive and display fire alarm, linkage control, fault alarm, supervision alarm, shielding, delay, self-test and other information from each zone controller, enter the corresponding state, and can issue control commands to the area controller.

      Network communication function: It can connect zones alarm controller, centralized alarm controller and fire control room graphic display device to realize local area network communication through EINet/EICAN; it has RS-232/485 serial communication interface, which can be connected with building automation or other systems, remote communication can be carried out through our remote monitoring system.

      Programming function: It can complete all programming through the keyboard of the controller itself, can input Chinese characters directly, and has built-in secondary standard Chinese character font. It can be used for annotation of Chinese characters in any device in the system and its location. It is very intuitive; it has extremely convenient screen editing function. Can automatically prompt for the location of the data error and give the correct range of data.


      Auxiliary functions:

      Black box function: It can automatically store historical records such as fire alarm, warning, supervision, linkage, fault, shielding, etc.

      Query function: It can query all fire alarm, warning, supervision, linkage, fault, shielding and programming information, and can query the required information in the most convenient way.

      Print function: It can automatically print real-time fire alarm, warning, supervision information and linkage action information, and can print parts list.

      Automatic switching between main and backup power: It can automatically switch between main and standby power, and has corresponding indications. The backup power has undervoltage protection function to avoid damage to the battery due to excessive discharge.

      Operation authority: In order to prevent unintentional personnel from misoperation, the operation level can be limited by password, and the password can be set arbitrarily.















       





       





      ? Ambient temperature: 0 °C ~ 40 °C; Relative humidity: ≤ 95 % (non-condensing)

      ? AC input voltage: 220V±10/15%?, 50Hz±1%

      ? AC input power: ≤240W

      ? DC backup: DC24V/24Ah fully sealed maintenance free battery

      ? Maximum loop capacity: 242 addressing points

      ? Maximum total capacity: 4840 addressing points

      ? Number of multi-line linkage control panels: ≤10 (each linkage panel has 12 sets of multi-line linkage buttons)

      ? Number of bus linkage control panels: ≤ 20 (60 buttons per panel)

      ? Bus length: ≤ 2000 meters (cross-sectional area ≥ 1.0mm2)

      ?Dimensions:545mm*485mm*1800mm( cabinet type)          

      1080mm*1120mm*1250mm (6000T piano type)


          


      Back